<LOGO>
FM Transmitter Measurement Report
Created: 2026-09-20 23-11-26
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 52 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 72 kHz 15666 24,2436
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,7 dBr 5,71 dBr 6,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 72 kHz MIN: 12 kHz % above 76 kHz: 24,2436 Acquired: 2026.09.20 23.10.22 Total samples: 15666 Equivalent time: 0:13:03 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600 800
FM Scope MAX: 6,3 dBr MIN: 4,7 dBr AVE: 5,71 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2026.09.20 23.10.22) 22.56 22.58 23.00 23.02 23.04 23.06 23.08 23.10 0 2 4 6 Pm [dBr]